Short answer
Yes, you can use an E7018 electrode for a root pass, and it is done. It works best when the joint has a backing strip or backing plate, or when the procedure specifically allows it. On an open-root pipe joint with no backing, many welders in North America prefer E6010 (or a similar cellulosic rod) for the root and use E7018 for the fill and cap passes. Whether 7018 is allowed for the root on a given job comes down to the welding procedure specification (WPS) and the code.
Open root vs backed joints
- Backed joint. A backing strip or plate sits behind the groove, so the weld pool has something to rest on. The risk of burning through is low, and 7018 is a reasonable choice. Training programs often have students run 7018 roots on backed plate.
- Open root. There is nothing behind the joint, and the root pass must fuse through the full thickness and form a bead on the inside. This is harder to do with 7018, which is why it is a less common choice.
If you are testing on pipe, check the test instructions first. Some tests require a certain root electrode, and others let you pick as long as the procedure is met.
Why 6010 is common for open roots
E6010 is a cellulosic electrode with a digging, forceful arc and a fast-freezing puddle. These features make it suited to open-root pipe welds:
- The arc penetrates well and helps keep the keyhole open.
- The puddle freezes quickly, so it is easier to control in vertical and overhead sections.
- It is more tolerant of a little variation in gap and fit-up.
E7018 is a low-hydrogen, iron-powder electrode with a softer arc and a more fluid puddle. On an open root, that fluidity can make it easier to burn through or trap slag in the root. The slag is also harder to see and remove from a narrow root.
Why some welders choose 7018 for the root
There are reasons for using 7018 for roots, depending on the job:
- Low hydrogen. It deposits weld metal with low hydrogen content, which helps on higher-strength or thicker steels that are sensitive to hydrogen cracking.
- One electrode for the whole joint. Using one rod simplifies the work and can suit some structural and shop settings.
- Local practice. In some regions and trades, 7018 roots are used more often than in US pipeline-style work.
These are not universal, and the best choice depends on what the code and procedure permit.
Technique tips
These are commonly shared among welders, but they are starting points, not rules:
- Use a root face. A land of about 1/8 inch (around 3 mm) on the bevel can help prevent burn-through. Follow the dimensions in your procedure.
- Keep a tight arc. A short arc length gives more control with a low-hydrogen electrode.
- Use a smaller electrode. 3/32 inch rods are commonly used for roots, where allowed.
- Set amperage carefully. Settings depend on the electrode, position and gap. Start from the manufacturer’s recommended range and adjust on test coupons. The stick welding amperage chart lists typical ranges.
- Check polarity. 7018 is normally run on DC electrode positive (DCEP), or on AC. Some welders try other polarity on open roots, but only do this if your procedure permits it.
- Clean carefully. Slag needs to be completely removed before the next pass. On a root, check for slag trapped at the sides.
- Keep the rod dry. Low-hydrogen electrodes absorb moisture, so store them in a rod oven or as the manufacturer recommends.
If you can reach the back side of a joint, back-gouging and welding from the other side can address slag or fusion concerns, but that usually does not apply to pipe.
Follow the WPS
The electrode used for each pass is normally written into the WPS, and changing it can mean the procedure or your qualification no longer covers the weld. If your WPS calls for 6010 on the root and 7018 on the fill and cap, using 7018 for the root would be a deviation. If it calls for 7018 throughout, then 6010 would be the deviation.
For more on how the root fits into the full joint, see the pipe welding process from root to cap, and for how fit-up affects the root, see pipe fit-up. If you are preparing for a test, the 6G test guide covers electrodes commonly used there.