Weld Inspection and Defects

Ultrasonic Testing (UT) in Welding

UT in welding stands for ultrasonic testing, a non-destructive method that uses sound waves to find internal weld flaws. Learn how it works and where it falls short.

On this page
  1. What UT means in welding
  2. UT vs NDT: are they the same?
  3. How ultrasonic weld testing works
  4. What UT can find in a weld
  5. PAUT and TOFD
  6. UT compared with other methods
  7. Limitations
  8. Who performs UT

What UT means in welding

In welding, UT stands for ultrasonic testing. It is a non-destructive testing (NDT) method that sends high-frequency sound waves into a weld and metal to look for internal flaws, without cutting or damaging the part.

Because sound travels through the material and reflects off anything that interrupts it, a trained technician can detect hidden flaws such as cracks, lack of fusion and slag that a visual inspection can’t see.

UT vs NDT: are they the same?

No. NDT stands for non-destructive testing, which is the general category. UT is one specific NDT method within it.

Other common NDT methods used on welds include:

  • Visual testing (VT)
  • Liquid penetrant testing (PT), covered in how dye penetrant testing works
  • Magnetic particle testing (MT)
  • Radiographic testing (RT), using X-rays or gamma rays

So every UT inspection is NDT, but not all NDT is UT.

How ultrasonic weld testing works

The basic setup is simple, even though doing it well takes training:

  1. A transducer (probe) converts electrical pulses into high-frequency sound waves, typically in the low megahertz range for welds, well above human hearing.
  2. A couplant, such as a gel, oil or water, is applied between the probe and the metal. Without it, air gaps would block the sound.
  3. The sound travels through the metal. When it meets a boundary, such as the back wall of the part or a flaw, part of the energy reflects back to the probe.
  4. The instrument displays the echoes. The time the echo takes to return indicates how deep the reflector is, and its amplitude gives a clue about its size.

For welds, technicians commonly use angle-beam probes, which send sound into the weld at an angle rather than straight down. This lets them scan the weld volume from the surface of the plate beside the weld. The probe is moved along and across the weld while the technician watches the display. The equipment is normally calibrated on reference blocks with known reflectors before use, and the procedure should follow the applicable code or specification.

What UT can find in a weld

UT is mostly used to find planar and volumetric internal flaws, including:

  • Cracks
  • Lack of fusion
  • Incomplete penetration
  • Slag inclusions
  • Porosity and voids
  • Laminations in the base metal

Cracks and lack of fusion are generally the main reasons UT is chosen, since these planar flaws are the most harmful. For more on how weld cracks arise, see why welds crack.

PAUT and TOFD

Two advanced forms of ultrasonic testing are widely used:

  • Phased array ultrasonic testing (PAUT) uses a probe with multiple elements whose timing is controlled electronically to steer and focus the beam. It can create cross-section images of the weld and often speeds up inspection.
  • Time-of-flight diffraction (TOFD) uses a pair of probes and measures sound diffracted from the tips of flaws, which is useful for sizing flaw height and for finding cracks.

Both give more recordable data than conventional manual UT, where the result is mainly the technician’s interpretation of a live screen.

UT compared with other methods

  • Versus radiography: UT uses no ionizing radiation, usually needs access to only one side of the weld, and tends to be better at detecting planar flaws such as cracks and lack of fusion. Radiography gives a permanent image and can be easier to interpret for volumetric flaws like porosity.
  • Versus visual, penetrant and magnetic particle: those methods are limited to the surface or near it, while UT can examine the full thickness of the weld.

Which method a project uses is set by the applicable code and contract.

Limitations

  • Operator skill matters. Results depend heavily on the technician’s training and experience.
  • Surface condition. Rough surfaces, heavy spatter or coatings can interfere with coupling. The scanning surface often needs preparation.
  • Geometry and material. Thin sections, complex shapes, and coarse-grained materials such as some stainless steel and cast welds can make interpretation difficult.
  • Flaw orientation. A flaw oriented unfavorably to the sound beam may be missed, which is why multiple angles are used.
  • Not every indication is a defect. Geometry can create false echoes, so indications need to be evaluated.

Who performs UT

UT is normally carried out by personnel qualified under a certification scheme, such as one based on ASNT’s recommended practice or ISO 9712, with levels indicating how much responsibility the person can take, such as performing tests or interpreting results. Requirements vary by industry and code, so check what your project calls for.

The complete guide to weld inspection and defects

Visual Weld Inspection: What to Look For
Read the guide

Keep exploring

Guides from other topics

All topics →